The test system and testing methodology

We proceeded to test the 3 Phobya pumps both idle and loaded. In the idle circuit, the pumps were run with the mere presence of the High Flow G1/4" Flow meter of Aquacomputer (appreciated for its low resistance to the liquid and for its precision), linked to the Aquaero 5 XT Controller (to detect the flow).In addition to this we have connected the pump to a simple, but large, bowl to act as a buffer, to have the pump always full of water so as not to create the classic cavitation phenomenon.

In the full load test we have included after the pump an EK waterblock, the Supreme HF - Full Copper model, with the standard Jetplate, combined upstream the pump with the Phobya radiator, model G-Changer 360 Ver 1.2 Black. We used a bi-distilled H2O solution as liquid mean. Below, in the table, the synthetic summary of the components used for testing.